AI Hub / WIS / 900 / 1996 / Document 17366

WIS Document: 17366

Model Context: 900 (1996)

Leaf Node
| | B1432 LH direction indicators shorted to ground Fault symptom The direction indicator lamp does not work, "TICK TACK" sound generated at double frequency. Conditions B1432 : The left-hand direction indicators are shorted to ground. Diagnostic procedure | 1. | Activate the direction indicator switch and check the power supply to the direction indicator lamps by taking readings as follows: | | • | across pin 2 of the connector for the front direction indicator lamps and a good grounding point. | | • | across the connector for the side direction indicators (yellow/black lead) and a good grounding point. | | • | between connector contact pin 2 of the rear direction indicator lamps and a good grounding point. The readings should change between 0 V and 12 V. | 2. | If it does not, connect a BOB and check the leads for shorting to ground as follows: | | • | across pin 1 of the ICE module connector and pin 2 of the front left-hand direction indicator lamp. | | • | across pin 48 of the ICE module connector and the connector for the left-hand side direction indicator (green/black lead). | | • | across pin 1 of the ICE module connector and pin 2 of the connector for the left-hand rear direction indicator lamp. | 3. | Connect a voltmeter between connector pins 1 and 48 or 70. Activate the direction indicators by selecting "ACT. OTHER FUNCT" from the scan tool menu and then "LH DIRECT. INDIC." or "RH DIRECT. INDIC." Check that the voltmeter reading changes between 0 V and 12 V with the ignition "ON". | 4. | If it does not, the fault is probably in the ICE module. Proceed to .

Canonical Workshop Redirect

For step-by-step instructions, interactive illustrations, and official wiring diagrams, refer to the human-optimized workshop page below.

Switch to Interactive WIS