WIS Document: 4032
Model Context: 900 (1998)
| |
Glass breakage sensor
Fault symptom
Grass breakage sensor does not trip the alarm.
Diagnostic procedure
1 Check the operation of the glass breakage sensor
| - |
Connect the ISAT scan tool.
| - |
Select "READ VALUES".
| - |
Select "GLASS BREAK SENSOR".
| - |
Jingle a bunch of keys or the like near the sensor.
The ISAT scan tool display should show a reading of between 10 and 255.
Is ISAT indicating the correct value?
|
yes
Continue with point 6.
|
no
Continue with point 2.
2 Check the operation of the glass breakage sensor
| - |
Disconnect the glass breakage sensor by unplugging the 4-pin connector.
| - |
Select "READ VALUES".
| - |
Select "GLASS BREAK SENSOR".
If the connector remains open, the ISAT scan tool display should show "0". Connect a jumper lead between pins 1 and 2 of the connector. The scan tool display should now show a reading of 255.
Is ISAT indicating the correct value?
|
yes
Change the glass breakage sensor.
|
no
Continue with point 3.
3 Check the operation of the electronic control module
| - |
Unplug connector H10-4.
| - |
Select "READ VALUES".
| - |
With the connector open, the ISAT scan tool display should show "0". With a jumper lead connected between pins 2 and 3 of connector H10-4, the scan tool display should show a reading of 255.
Is ISAT indicating the correct value?
|
yes
Continue with point 5.
|
no
Continue with point 4.
4 Check the wiring connected to the electronic control module
Conduct a continuity test on the cable assembly between
| - |
connector H10-4, pin 2 and the control module, pin 7.
| - |
connector H10-4, pin 3 and the control module, pin 5. The resistance should be < 1 ohm.
Is the resistance correct?
|
yes
Continue with point 6.
|
no
Repair or replace the wiring harness.
5 Check the wiring connected to the glass breakage sensor
Conduct a continuity test on the cable assembly between
| - |
connector H10-4 (pin 2) and the glass breakage sensor (pin 1).
| - |
connector H10-4 (pin 3) and the glass breakage sensor (pin 2). The resistance should be < 1 ohm.
Is the resistance correct?
|
yes
Carry out a visual inspection of the sensor and connector.
|
no
Repair or replace the wiring harness. If nothing can be found that can be corrected, change the glass breakage sensor.
6 Final check
| - |
Disconnect the ISAT scan tool.
| - |
Close all doors.
| - |
Arm the alarm and wait until the LED flashes at the rate of 1 flash every 2 seconds.
| - |
Jingle a bunch of keys close to the sensor.
Does the alarm go off?
|
yes
The remedial measures taken were correct or the fault is of intermittent nature.
|
no
See "Before replacing a control module".