WIS Document: 8231
Model Context: 900 (1995)
| |
Replacement of oxygen sensor
| 1. |
Disconnect the oxygen sensor's cables, undo the cable clamp and the clip and lift up the car.
| Important
|
Do not twist the cables. The oxygen sensor is very sensitive to blows and impacts and must be handled with care.
|
| 2. |
Remove the oxygen sensor.
| 3. |
Take out the new oxygen sensor and apply Molycote 1000 (30 20 971) on the threads to prevent seizure.
| Important
|
It is important that the connection between the oxygen sensor and the nipple is impervious to gas.
|
| 4. |
Fit the oxygen sensor.
Tightening torque 55 Nm (41 lbf ft).
| 5. |
Lower the car, reconnect the cables and fit the hose clamp and the clip.