Replacement of secondary air switching valve
| 1. |
Undo the hose clamps and remove the air hoses.
| 2. |
Undo the vacuum hose and remove the valve. Check the functioning by using the vacuum pump or by blowing into the valve.
| 3. |
Fit the new valve and reconnect the vacuum hose.
| 4. |
Refit the air hoses.